Design and Performance Evaluation of Solar Liquid Desiccant System

Libin R S, Mar Athanasius College of Engineering Kothamangalam; Prof. Jacob Kuriakose ,Mar Athanasius College of Engineering Kothamangalam; Prof. Sunil Mathew Roy, Mar Athanasius College of Engineering Kothamangalam; Adarsh Kumar, Armstech Engineers Palarivattom, Ernakulam

HVAC, CLTD, Desiccant wheel, solar energy, Ducting, HAP

Human comfortness is essential now a day because of the improvement in life style and increasing atmospheric temperature. Electrical air conditioning machines are not most suitable for large buildings because of the higher power consumption and shorter life. Central air conditioning or chilled water system is more reliable for easy operation with a lower maintenance cost for large building. With large buildings such as commercial complex, auditorium, office buildings are provided with central air conditioning system. Educational and research institutions, Hotels, Hospitals, malls etc. are also need human comfortness, as the population of student community increase year by year. The effective design of central air conditioning or a chiller system can provide lower power consumption, capital cost and improve aesthetics of a building. This paper establishes the results of cooling load calculation of different climate conditions by installing dehumidifier. By using CLTD method and Carrier program then the results are compared for a single-story building which is a part of an institute. Cooling load items such as, Electrical equipments, people heat gain, lighting heat gain, infiltration and ventilation heat gain can easily be putted to the MS-Excel programme. The programme can also be used to calculate cooling load due to walls and roofs. And results were compared with the standard data given by ASHRAE and CARRIER Fundamental Hand Books, hourly analysis programme and results are satisfactory. It is also seen that in this paper cooling requirement of without dehumidifier is about 20 % more as compare to with dehumidifier for climate condition of Thiruvanathapuram, Kerala in India. It will be a significant for a large commercial building.
    [1] ASHRAE, Handbook of Fundamentals, Ch. 28. American Society of Heating, Refrigerating and Air- Conditioning Engineers, U.S.A. (1997). [2] Cooling load calculation manual prepared by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., U.S. Department of Housing and Urban Development. [3] A Bhatia, HVAC Made Easy: “A Guide of Heating and Cooling Load Estimation”, PDH online course M196 (4PDH). [4] Handbook of Air Conditioning System Design /Carrier Air Conditioning Co. by Carrier Air Conditioning Pty. Ltd. [5] Andersson,B., Wayne P. and Ronald K., " The impact of building orientation on residential heating and cooling" , Energy and Buildings,1985; 8; 205-224. [6] Al-Rabghi O. and Khalid A. , " Utilizing transfer function method for hourly cooling load calculations" Energy Conversion and Management,1997; 38; 319-332. [7] Shariah A, Bassam S., Akram R. and Brhan T.," Effects of absorptance of external surfaces on heating and cooling loads of residential buildings in Jordan" Energy Conversion and Management,1998; 39; 273-284. [8] Kulkarni K., P.K. Sahoo and Mishra M., “Optimization of cooling load for a lecture theatre in a composite climate in India” Energy and Buildings, 2011; 43; 1573-1579. [9] Suziyana M. D., Nina S. N., Yusof T. M. and. Basirul A. A. S., “Analysis of Heat Gain in Computer Laboratory and Excellent Centre by using CLTD/CLF/SCL Method” Procedia Engineering, 2013; 53; 655 – 664. [10] Hani H. Sait, “Estimated Thermal Load and Selecting of Suitable Air Conditioning Systems for a Three Story Educational Building” Procedia Computer Science, 2013; 19; 636 – 645. [11] Suqian Y., Jiaping L., Ge Xiangrong and Xiang H., “The Research of Cooling Load and Cooling Capacity Calculation Methods of Spinning Workshop” Procedia Environmenta. [12] Foudaa A., Melikyan Z., Mohamed M.A. and Elattar H.F., “A modified method of calculating the heating load for residential buildings” Energy and Buildings, 2014; 75; 170–175. [13] Lin Duanmu , Wang Z., Zhai Z.and Xiangli L., “A simplified method to predict hourly building cooling load for urban energy planning” Energy and Buildings, 2013; 58; 281–291. [14] Christian , Gueymard and Thevenard D., “Monthly average clear-sky broadband irradiance database for worldwide solar heat gain and building cooling load calculations” Solar Energy, 2009; 83; 1998–2018. [15] Abdullatif E., Ben-Nakhi, Mohamed A., and Mahmoud, “Cooling load prediction for buildings using general regression neural networks” Energy Conversion and Management, 2004; 45; 2127–2141. [16] Fernando Simon, Westphal,F.S. and Roberto L., “The use of simplified weather data to estimate thermal loads of non-residential buildings” Energy and Buildings, 2004; 36; 847-854. [17] Mehmet Azmi ,Aktacir M.A., Buyukalaca O, and Tuncay Y., “A case study for influence of building thermal insulation on cooling load and air-conditioning system in the hot and humid regions” Applied Energy, 2010; 87; 599–607. [18] Tingyao Chen and Zhun Yu, “A statistical method for selection of sequences of coincident weather parameters for design cooling loads calculations” Energy Conversion and Management, 2009; 50; 813–821. [19] Naouel Daouas, “A study on optimum insulation thickness in walls and energy savings in Tunisian buildings based on analytical calculation of cooling and heating transmission loads” Applied Energy, 2011; 88; 156–164.
Paper ID: GRDJEV02I060171
Published in: Volume : 2, Issue : 6
Publication Date: 2017-06-01
Page(s): 261 - 266