Numerical Investigation of Heat Transfer Characteristics Using Different Discrete Rib Arrangements

Sandip T. Jadhav, PES's Modern College of Engineering, Pune; R. D. Shelke ,PES's Modern College of Engineering, Pune; H. N. Deshpande ,PES's Modern College of Engineering, Pune

Rib Arrangement, Heat Transfer Enhancement, Rib Spacing, Rib Angle

Numerical study was carried out to study effect of different discrete rib arrangements on heat transfer performance. These rib arrangements include variously angled ribs, different. Spacing and also different angle combinations. Standard k-ε model is used for turbulence modelling. This study is carried out at Reynolds no. 22384 which was selected from previous studies. Different rib arrangements like inline and staggered for 30⁰, 45 and 60, discrete V’s arrangement with different spacing, diamond like discrete rib arrangement with half and complete obstruction, inline and staggered connected V’s and angle combination rib arrangements are studied numerically in this study. It is observed that 45 inline V-shape rib arrangement shows better Thermal Enhancement Factor (TEF) as compared to other arrangements and value of TEF is observed to be 1.0011. Ribs arranged in discrete V’s shape with different spacing shows comparatively less heat transfer enhancement.
    [1] Rajendra Karwa and V. Srivastava, (2013), “Thermal Performance of Solar Air Heater Having Absorber Plate with V-Down Discrete Rib Roughness for Space-Heating Applications”, Journal of Renewable Energy Volume, Article ID 151578, 113-126. [2] Sandip T. Jadhav, R. D. Shelke, H. N. Deshpande, (2016), “Numerical and Experimental Investigation of Heat Transfer Using Discrete Ribs”, International Engineering Research Journal (IERJ) Special Issue Page 793-800, ISSN 2395-1621 [3] Abhilash Kumar and S. Prabhakar, (2014), “Numerical investigation of heat transfer characteristics of square duct with internal ribs”, IJIRSET, volume 3,1179-1185 [4] Xingjun Fang, Zixuan Yang, Bing-Chen Wang, Mark F. Tachie, Donald J.Bergstrom, (2015) “Highly-disturbed turbulent flow in a square channel with V-shaped ribs on one wall”, International Journal of Heat and Fluid Flow, 56, 182–197 [5] Chao Ma, Xiaoling Chen, Jianfei Wang, Shusheng Zang, Yongbin Ji, (2015), “An experimental investigation of heat transfer characteristics for steam cooling and air cooling in a rectangular channel roughened with parallel ribs”, Experimental Thermal and Fluid Science 64, 142–151 [6] Satyanand Abraham, Rajendra P. Vedula, (2016), “Heat transfer and pressure drop measurements in a square cross-section converging channel with V and W rib turbulators”, Experimental Thermal and Fluid Science, 70, 208–219 [7] Linqi Shui, Jianmin Gao, Xiaojun Shi, Jiazeng Liu, (2013), “Effect of duct aspect ratio on heat transfer and friction in steam-cooled ducts with 60 degree angled rib turbulators”, Experimental Thermal and Fluid Science ,49, 123–134
Paper ID: GRDJEV02I030058
Published in: Volume : 2, Issue : 3
Publication Date: 2017-03-01
Page(s): 86 - 104