Effect of MTMD on Seismic Demand of Base-Isolated Buildings

Billimoria K.P, SVIT, Vasad; Dr. Soni D.P ,SVIT, Vasad

Ground motions, Mass ratio, MTMD, TMD, Tuning frequency

The effectiveness of multiple tuned mass dampers (MTMD) for vibration control of structure over a single tuned mass damper (STMD) is investigated in the paper. A base isolated structure supported with MTMD is considered and the governing differential equations of motion are derived. The response of the structure under four selected earthquake ground motions is obtained by solving the equations of motion numerically using the state space method. A parametric study is also conducted to investigate the effects of important parameters such as number of dampers in MTMD, damper frequency spacing, mass ratio, tuning ratio. It is found that for a given structural system and level of excitation an optimum value of the parameters (i.e. frequency spacing, tuning ratio) exists at which the peak displacement of structure attains its minimum value. The response time history of the structure with STMD and MTMD with respect to their optimum parameters is compared. It is found that the MTMD is more effective in controlling the response of the structure in comparison with the STMD having the same mass.
    [1] Abe, M. and Igusa, T., “Tunes mass damper for closely spaced natural frequency.”, Earthquake Engineering and Structure Dynamics, 24, 247–261, 1995. [2] Carneiro, R. B., Avila, S. M., and De Brito, J. V., “Parametric study on multiple tuned mass dampers using interconnected masses.”, International Journal of Structural Stability and Dynamics, 8, 187–202, 2008. [3] Jangid, R. S. and Datta, T. K., “Performance of multiple tuned mass dampers for torsionally coupled system.” Earthquake Engineering And Structural Dynamics, 26, 307-317, 1997. [4] Pisal, A. Y. and Jangid, R. S., “Seismic response of multi-story structure with multiple tuned mass friction dampers.” Journal of Advance Strucural Engineering, 6, 1-13, 2014. [5] Singh, M. P., Singh, S. and Moreschi, L.M., “Tuned mass dampers for response control of torsional buildings.” Earthquake Engineering and Structural Dynamics, 31, 749–769, 2002. [6] Taniguchi, T., Kiureghian, A. and Melkumyan, M., “Effect of TMD on displacement demand of base isolated structures.” Engineering Structures, 30, 3478 – 3488, 2008. [7] Xu, K. and Igusa, T., “Dynamic characteristics of multiple substructures with closely spaced frequencies.” Earthquake Engineering and Structure Dynamics, 21, 1059–1070, 1992.
Paper ID: GRDCF001110
Published in: Conference : Recent Advances in Civil Engineering for Global Sustainability (RACEGS-2016)
Page(s): 315 - 319